FLIGHT CONTROLL WIRE
AWM 22-86-10 P0002 SHEET1
FROM
FMGS# 1 - 1CA1 - AE/4B P/N E0170FA2200
TO
1831VT 2X P/N EN3155-016M2222
P/N: ASNE0272TK26
B/R
1S
115 cm
AWG 26
-------------------------------------------
CIDS 1 CLASS 3 FAULTS MESSAGE
EVA
DURING CIDS 1 CLASS 3 FAULTS TEST FOUND
FOLLOWING
DEFECTS:
1. INOPERATIVE READING LIGHTS PCB ON POSITION
01L,
21R, 25R. TROUBLESHOOTING TO BE PERFORMED IAW TSM
33-25-00-810-802-A REV.96.
2. INOPERATIVE WORK LIGHT ON POSITION APT 1.
TROUBLESHOOTING TO BE PERFORMED IAN TSM
33-27-00-810-801-A REV.96.
SPC
READING LIGHT FAULT ON THE PRINTED CIRCUIT BOARD
(PCB) OF THE READING LIGHTS TROUBLESHOOTING
PERFORMED
IAW TSM 33-25-00-810-802-A REV.96.
SPC
CABIN ATTENDANT WORK LIGHT FAULT TROUBLESHOOTING
PERFORMED IAW TSM 33-27-00-810-801-A REV. 96.
EVA
DURING READING LIGHT FAULT ON THE PRINTED
CIRCUIT
BOARD (PCB) OF THE READING LIGHTS
TROUBLESHOOTING TAW
TSM 33-25-00-810-802-A REV. 96 FOUND INOPERATIVE
READING LIGHTS ON POSITION 01C, 210 AND 25A.
READING
LIGHT TO BE REPLACED IAW AMM 23-73-64 PB.401 REV.115
EVA
DURING CABIN ATTENDANT WORK LIGHT FAULT
TROUBLESHOOTING IAW TSM 33-27-00-810-801-A REV.96.
FOUND INOPERATIVE READING LIGHTS ON POSITION
(FIN:
214LZ). CABIN ATTENDANT WORK LIGHT LAMP (FIN:
214LZ)
TO BE REPLACED IAW AMM 33-27-12 PB.401 REV.115
REM
READING LIGHTS ON POSITION 010, 21E AND 25A
REMOVED
IAW AMM 23-73-64-000-001-A REV.115.
READING
LIGHTS
P/N:
2LA455953-23
B/N
QTY:
3EA
REM
CABIN ATTENDANT WORK LIGHT LAMP ON POSITION
(FIN:
214LZ) REMOVED IAW AMM 33-27-12-000-001-A REV. 115
LAMP
P/N:
BGH005678-06
B/N
QTY:
1EA
INS
READING LIGHTS ON POSITION 01c, 21E AND 25A
INSTALLED
TAN AMM 23-73-64-400-001-A REV.115.
READING
LIGHTS
P/N:
2LA455953-23
B/N:
QTY:
3EA
INS
CABIN ATTENDANT WORK LIGHT LAMP ON POSITION
(FIN:
214LZ) INSTALLED IAW AMM 33-27-12-400-001-A REV. 115
LAMP
P/N:
8GH005678-06
B/N:
QTY:
1EA
OPC
OPERATIONAL TEST OF THE PASSENGER READING LIGHT
SYSTEM PERFORMED IAW AMM 33-25-00-710-001-A REV. 115
FUC (CAB)
FUNCTIONAL TEST OF THE PASSENGER READING LIGHT
PERFORMED IAW AMM 23-73-64-720-001-A REV. 115.
OPC (CAB)
OPERATIONAL TEST OF Cabin ATTENDANT WORK LIGHTS
PERFORMED IAW AMM 33-27-12-400-001-A PARA "F"(1) REV 115